IEC 60601-1-2 EMC Testing

IEC 60601-1-2 EMC Compliance Testing for Medical Devices

IEC 60601-1-2 Edition 4.0/4.1 specifies electromagnetic compatibility requirements for medical electrical equipment. Compatible Electronics provides comprehensive 60601-1-2 EMC testing as an FDA ASCA recognized laboratory, ensuring your medical devices meet safety and performance requirements.

What is IEC 60601-1-2?

IEC 60601-1-2 is the collateral standard for electromagnetic disturbances in medical electrical equipment. Edition 4 introduced a risk management approach requiring manufacturers to identify essential performance and demonstrate that EMC phenomena do not create unacceptable risks.

Edition 4.0/4.1 Key Changes

  • Risk management integration throughout EMC testing
  • Essential performance identification required
  • Professional healthcare vs home healthcare environment distinction
  • Increased immunity test levels for certain environments
  • New proximity field immunity requirements
  • Wireless coexistence considerations
  • Updated emissions limits alignment with CISPR 11

EMC Testing Services

Emissions Testing

  • Radiated emissions (CISPR 11 Group 1/2, Class A/B)
  • Conducted emissions (150 kHz - 30 MHz)
  • Harmonic current emissions (IEC 61000-3-2)
  • Voltage fluctuations and flicker (IEC 61000-3-3)
  • Emissions classification based on intended use environment

Immunity Testing

  • ESD immunity (IEC 61000-4-2) - up to ±8 kV contact, ±15 kV air
  • Radiated RF immunity (IEC 61000-4-3) - 80 MHz to 2.7 GHz
  • EFT/Burst immunity (IEC 61000-4-4)
  • Surge immunity (IEC 61000-4-5)
  • Conducted RF immunity (IEC 61000-4-6)
  • Power frequency magnetic field immunity (IEC 61000-4-8)
  • Voltage dips and interruptions (IEC 61000-4-11)
  • Proximity field immunity from RF wireless equipment

Intended Use Environments

Professional Healthcare Facility Environment

Higher immunity test levels for devices used in hospitals, clinics, and professional healthcare settings where electromagnetic environment is more severe.

Home Healthcare Environment

Testing specific to residential electromagnetic environments for devices used by patients and caregivers at home.

Special Environments

MRI rooms, surgical suites, emergency medical services - each with unique electromagnetic considerations and test requirements.

Life-Supporting Equipment

Enhanced testing requirements for devices where EMC-related failures could result in patient harm or death.

Essential Performance Documentation

Risk-Based Approach to EMC

We work with manufacturers to properly identify and document essential performance - the clinical functions that must be maintained during and after EMC disturbances. This risk-based approach is fundamental to Edition 4 compliance.

Essential performance must be identified before EMC testing begins and verified throughout the test program.

Standards We Test To

International

  • IEC 60601-1-2 Ed. 4.0 (2014)
  • IEC 60601-1-2 Ed. 4.1 (2020)
  • Referenced IEC 61000 series

European

  • EN 60601-1-2:2015
  • EN 60601-1-2:2021
  • Harmonized under Medical Device Regulation

North America

  • AAMI/IEC 60601-1-2
  • FDA ASCA Recognition (TL-81)
  • FDA-accepted test reports

Emissions Standards

  • CISPR 11 (EN 55011)
  • Group 1 and Group 2 devices
  • Class A and Class B limits