Conducted Immunity Testing Services
Conducted immunity testing evaluates your product's ability to operate correctly when exposed to radio frequency disturbances induced on cables and interconnections. Compatible Electronics provides comprehensive IEC 61000-4-6 testing services.
What is Conducted Immunity Testing?
RF energy from radio transmitters and other sources can couple onto cables connected to electronic equipment, potentially causing malfunctions. IEC 61000-4-6 testing simulates these real-world conditions using controlled RF signals injected onto power and signal lines.
Our Testing Capabilities
Frequency & Levels
- Frequency range: 150 kHz to 80 MHz
- Test levels: 1 V to 30 V (0 dBμV to 140 dBμV)
- 80% AM modulation, 1 kHz sine wave
Injection Methods
- CDN (Coupling/Decoupling Network) method
- Direct injection method
- Current probe (BCI) method available
Standards Covered
IEC / EN Standards
- IEC 61000-4-6 - Conducted RF Immunity
- EN 61000-4-6 - European Standard
- IEC 61000-6-1/6-2 - Generic Standards
Product-Specific
- IEC 60601-1-2 - Medical Device EMC
- EN 55035 / CISPR 35 - Multimedia Equipment
- IEC 61326-1 - Measurement Equipment
International
- KS C 9610-4-6 - Korea Standard
Test Levels
3
Level 3
10 V rms (20 dBμV)
4
Level 4
30 V rms (30 dBμV)
Higher levels available on request
Ports and Cables Tested
AC/DC Power Cables
Signal and Control Cables
Communication Cables
I/O Interfaces
Any Cable Longer Than 3 Meters
Coupling Methods
🔌
CDN-M Type
For shielded/unshielded cables
📞
CDN-T Type
For telecommunications
📦
EM-Clamp
For complex cable bundles
⚡
BCI Probe
Bulk Current Injection