Compatible Electronics provides NVLAP accredited product family and specialty EMC testing for alarm systems, lighting equipment, professional AV, DC power supplies, broadcast receivers, and telecommunications network equipment. Our ILAC MRA recognized test reports support CE marking and global market access from three Southern California locations.
Product family EMC standards provide tailored emissions limits and immunity requirements specific to a product's function, installation environment, and safety criticality. For many product categories — alarm systems, lighting, professional AV, power supplies, broadcast receivers, and telecom equipment — a product family standard is either required for CE marking or provides more appropriate test conditions than a generic standard.
Compatible Electronics holds direct NVLAP accreditation for all six specialty product EMC standards covered in this section — enabling manufacturers to test to the most appropriate standard for their product, from a single accredited California laboratory, with ILAC MRA recognized reports accepted by EU market surveillance authorities worldwide.
By utilizing Compatible Electronics NVLAP accredited specialty product testing (Lab Code 200527-0) and ILAC MRA recognition, you can expect:
Direct accreditation for the right standard — not just generic EMC, but the specific product family standard your product requires
ILAC MRA recognized test reports — CE marking accepted by EU market surveillance without overseas retesting
Emissions + immunity in one lab — complete CE marking EMC package from a single California engagement
Multi-market efficiency — specialty standard + FCC Part 15 + ICES + RCM from one test session
Function-specific performance criteria expertise — safety-critical alarm systems, audio quality, DC output stability, and more
Pre-compliance testing available — identify issues before formal certification to avoid retesting delays
🔍 Witness your testing in person — customers are welcome to observe at any Southern California location: Lake Forest (949-587-0400) · Brea (714-579-0500) · Newbury Park (805-480-4044)
Safety-critical EMC testing where no false alarms and no failure to alarm are mandatory performance requirements
Product family EMC standards for lighting equipment and professional AV installations — distinct from consumer multimedia standards
NVLAP accredited EN 55015 / CISPR 15 emissions testing for electrical lighting equipment — covering the full 9 kHz to 300 MHz frequency range critical for LED driver switching frequencies. Also accredited for EN 61547 immunity and ICES-005 Canada, enabling the complete lighting EMC package from one lab.
NVLAP accredited EN 55103-1 emissions and EN 55103-2 immunity for professional audio, video, and entertainment lighting control equipment. Covers all five electromagnetic environments (E1–E5) including broadcast studios, live event venues, and post-production facilities. Function-specific performance criteria: audio quality (THD, noise floor), video integrity, and DMX lighting control accuracy.
Specialty EMC standards for DC power supplies, broadcast receivers, and telecom network infrastructure
NVLAP accredited IEC/EN 61204-3 (2001) EMC testing for low-voltage DC output power supply units — SMPS, linear regulated supplies, DC-DC converters, DIN-rail industrial power supplies, and PoE injectors. DC output performance monitoring during all immunity tests. Combined IEC/EN 61204-3 + EN 55032 + FCC Part 15 from one session.
NVLAP accredited EN 55013 / CISPR 13 emissions testing for sound and television broadcast receivers — AM/FM radios, DAB+ receivers, TV receivers, satellite set-top boxes, and associated equipment. Multiple version accreditation for legacy compliance maintenance. Also accredited for EN 55032 (the successor standard) at all three locations for new CE marking projects and EN 55013-to-EN 55032 transition testing.
NVLAP accredited ETSI EN 300 386 V1.6.1 EMC testing for telecommunications network equipment installed in telecom centres and data centres — routers, switches, transmission systems, VoIP PBX, and DSLAM equipment. Radiated emissions to 6 GHz, -48 VDC telecom port testing, and ITU-T K series surge levels on subscriber lines. Combined EN 300 386 + FCC Part 15 + ICES-003 multi-market from one session.
NVLAP Lab Code 200527-0 — accreditation effective 2025-06-05 through 2026-06-30:
| Standard | Product Category | Type | Locations |
|---|---|---|---|
| EN 50130-4 (2011) | Intrusion, fire, CCTV, access control alarm systems | Immunity | All 3 |
| EN 50130-4 (1995)+A1+A2 | Fire and intrusion alarm systems (legacy) | Immunity | LF, Brea |
| EN 55015 (2013) / CISPR 15 Ed 8.0 | Lighting equipment and lamp control gear | Emissions | LF, NP |
| EN 61547 / IEC 61547 (2009) | General lighting purposes — immunity | Immunity | Newbury Park |
| ICES-005 Issue 5 (Dec 2018) | Lighting equipment — Canada | Emissions | All 3 |
| EN 55103-1 (2009) | Professional audio, video, and entertainment lighting | Emissions | Newbury Park |
| EN 55103-2 (2009) | Professional audio, video, and entertainment lighting | Immunity | Newbury Park |
| IEC/EN 61204-3 (2001) | Low-voltage DC output power supply units | Emissions + Immunity | Brea, NP |
| EN 55013 (2013) | Sound and television broadcast receivers | Emissions | Newbury Park |
| EN 55013 (2001)+A1+A2 | Broadcast receivers (legacy versions) | Emissions | LF, Brea |
| ETSI EN 300 386 V1.6.1 (2012-09) | Telecommunications network equipment | Emissions + Immunity | LF, NP |
LF = Lake Forest/Silverado · NP = Newbury Park · All 3 = Lake Forest/Silverado, Brea, and Newbury Park