Korean KC/KCC Certification Testing
Compatible Electronics is directly accredited for Korean KN and KS C standards — not just equivalent international standards. Our NVLAP scope includes KN 32, KN 35, KS C 9832, KS C 9835, KS C 9610-4 series, KCC Notice 2008-39, and all RRA EMI/EMS notices, at all three California locations.
NVLAP AccreditedILAC MRA RecognizedKN 32 / KN 35 Direct AccreditationAll 3 CA Locations
KC Mark Categories
EMI
KC EMC — Emissions
- KN 32, KS C 9832, KCC Notice 2008-39, RRA EMI notices
- Class A and Class B digital/multimedia equipment
- Radiated and conducted emissions testing
EMS
KC EMS — Immunity
- KN 35, KS C 9835, KS C 9610-4 series, KCC Notice 2008-38, RRA EMS notices
- ESD, radiated RF, EFT/Burst, surge, conducted RF, magnetic field, voltage dips
- All three California locations accredited
Telecom
KC Telecom — Radio
- RRA radio notices for wireless equipment (WiFi, Bluetooth, short range devices)
- RF performance testing aligned with FCC ANSI C63.10 measurements
- Contact us to confirm scope for specific wireless product types
Accredited Korean EMC Emissions Standards
KN Series
KN 32 (Current Korean Multimedia Standard)
- KN 32:2015 (Annex 11) — accredited at Lake Forest/Silverado and Brea
- KN 32:2013 (Annex 16) — accredited at Lake Forest/Silverado and Brea
- Radiated emissions 30 MHz – 1 GHz; conducted emissions 150 kHz – 30 MHz
KS C Series
KS C 9832 (IEC/CISPR Harmonized)
- KS C 9832:2023 — MOD CISPR 32:2015; accredited at Brea
- KS C 9832:2019 — MOD CISPR 32:2015; accredited at Lake Forest/Silverado and Brea
- KS C 9610-3-2:2020 — harmonic current; all three locations
- KS C 9610-3-3:2020 — voltage fluctuations; all three locations
KCC / RRA
Legacy KCC and RRA EMI Notices
- KCC Notice 2008-39 — all three locations
- RRA Announce 2009-9, 2010-05 — all three locations
- RRA Notifications 2011-05, 2011-18, 2011-24 — all three locations
- RRA 2012-13/21, 2013-3/24, 2014-8/37 — all three locations
Accredited Korean EMC Immunity (EMS) Standards
KN / KS C
KN 35 & KS C 9835
- KN 35:2015 (Annex 11-2) — Lake Forest/Silverado
- KN 35:2015 (Annex 15) — Lake Forest/Silverado and Brea
- KS C 9835:2019 (MOD CISPR 35:2016) — all three locations
KS C 9610-4
Immunity Test Series
- KS C 9610-4-2:2017 — ESD; all three locations
- KS C 9610-4-3:2017 — Radiated RF; all three locations
- KS C 9610-4-4:2020 — EFT/Burst; all three locations
- KS C 9610-4-5:2020 — Surge; all three locations
- KS C 9610-4-6:2020 — Conducted RF; all three locations
- KS C 9610-4-8:2017 — Magnetic field; all three locations
- KS C 9610-4-11:2020 — Voltage dips; all three locations
KCC / RRA EMS
Legacy EMS Notices
- KCC Notice 2008-38 — Brea and Newbury Park
- RRA Notifications 2011-06, 2011-17, 2011-25 — all three locations
- RRA 2012-14/22, 2013-04/25, 2014-09/38 — all three locations
Real-World Testing Examples
Smart TV — KC EMI + EMS Combined
A display manufacturer required KC EMC certification for a 65-inch smart television for the Korean market. Compatible Electronics performed KN 32:2015 (Annex 11) radiated and conducted emissions testing at Lake Forest/Silverado (Class B) and KN 35:2015 (Annex 15) immunity testing covering ESD, radiated RF, EFT/Burst, surge, and conducted RF. The combined EMI/EMS package was accepted by the Korean in-country agent for KC mark application. Parallel EN 55032 + EN 55035 CE marking testing was performed in the same session.
Industrial Control System — KCC Notice 2008-39 + KS C 9610-4 Series
An industrial automation company needed KC EMC compliance for a PLC-based motor control system. Compatible Electronics performed KCC Notice 2008-39 conducted and radiated emissions (Class A) and KS C 9610-4-2, 4-3, 4-4, 4-5, 4-6, and 4-11 immunity testing. Combined ICES-003 Issue 7 Canadian testing was completed from the same emissions measurements, delivering dual-market compliance from one session.
WiFi/BLE IoT Module — KC EMC + Aligned RF Data
A semiconductor manufacturer required KC certification for a WiFi/BLE combo module. Compatible Electronics performed KN 32:2015 emissions testing for KC EMC at all three locations, and coordinated with the Korean in-country representative for KC Telecom filing using RF performance data from the FCC ANSI C63.10 test session — leveraging a single measurement set for both FCC and KC Telecom submissions.
Why Choose Compatible Electronics?
✓
NVLAP Accredited (Lab Code 200527-0)
ILAC MRA recognized — test reports accepted by Korean certification bodies for KC mark applications.
✓
Direct Korean Standard Accreditation
KN 32, KN 35, KS C 9832, KS C 9835, KS C 9610-4 series, KCC Notice 2008-39, and all RRA notices in our NVLAP scope.
✓
Accredited at All 3 Locations
Most Korean EMC standards accredited at Lake Forest/Silverado, Brea, and Newbury Park.
✓
Combined FCC + CE + KC Testing
Single test session for multiple markets — reduce cost and time-to-certification.
✓
Pre-Compliance Testing
Identify Korean EMC issues before formal testing to avoid retesting costs.
✓
3 California Locations
Lake Forest/Silverado, Brea, and Newbury Park — fast turnaround options available.
Ready for Korean KC/KCC Certification Testing?
Contact us for Korean KC and KCC certification testing services.
Also reach us at: Brea 714‑579‑0500 · Newbury Park 805‑480‑4044