Radiated immunity testing evaluates your product's ability to operate correctly when exposed to radio frequency electromagnetic fields. Compatible Electronics provides comprehensive IEC 61000-4-3 radiated immunity testing for all product categories.

What is Radiated Immunity Testing?

Radiated immunity (also called radiated susceptibility) testing determines whether your electronic product can withstand electromagnetic fields from sources like radio transmitters, wireless devices, and other RF emitters. This testing is critical for CE marking, medical device approval, and industrial equipment certification.

Our Testing Capabilities

Frequency & Field Strength

  • Frequency range: 80 MHz to 6 GHz
  • Field strengths: 1 V/m to 30 V/m
  • Higher levels available on request

Test Parameters

  • Amplitude modulation: 80% AM, 1 kHz sine wave
  • Anechoic chamber testing environment
  • Uniform field area calibration

Monitoring

  • Real-time monitoring of EUT performance
  • Automated frequency stepping
  • Detailed data logging

Standards Covered

IEC Standards

Test Levels Available

1

Level 1: 1 V/m

Light industrial environment

2

Level 2: 3 V/m

Residential/commercial

3

Level 3: 10 V/m

Industrial environment

4

Level 4: 30 V/m

Heavy industrial

Performance Criteria

We evaluate your product's performance during and after testing according to the applicable standard's criteria:

A

Criterion A

Normal performance within specifications

B

Criterion B

Temporary degradation, self-recoverable

C

Criterion C

Temporary loss of function, operator intervention needed

Industries Requiring Radiated Immunity Testing

Industrial Control Equipment
Laboratory & Test Equipment
Information Technology Equipment
Multimedia & Audio/Video Equipment
Alarm & Security Systems

Accredited Standard Versions & Locations

Compatible Electronics holds NVLAP accreditation for all major editions of IEC 61000-4-3, Korean equivalents, and the AS/NZS MOD version. See the full accreditation scope for details.

StandardDescriptionLocations
IEC 61000-4-3 Ed. 3.2 (2010-04)Current edition — referenced by EN 61000-6-1, EN 61000-6-2, IEC 60601-1-2 Ed.4, IEC 61326-1 (2012), EN 55035Lake ForestBreaNewbury Park
IEC 61000-4-3 Ed. 3.0 (2006) + A1 (2007)Previous consolidated edition — product standards 2007–2012Lake ForestBreaNewbury Park
IEC 61000-4-3 Ed. 3.0 (2006-02)Earlier third edition — legacy submissionsLake ForestBreaNewbury Park
IEC/EN 61000-4-3 Ed. 2.1 (2002) + A1Second edition — older CE marking submissionsLake Forest
KS C 9610-4-3; KN 61000-4-3Korean equivalents — required for Korean KC/KCC certification. See KN22 and KN24 learning page.Lake ForestBrea
AS/NZS 61000.4.3 (MOD IEC 61000-4-3:2010)Australian/NZ equivalent — required for RCM certificationLake ForestBreaNewbury Park

🔎 The tested frequency range depends on the product standard, not just IEC 61000-4-3 alone. IEC 60601-1-2 Ed.4 extends to 2.5 GHz; EN 55035 extends to 2.7 GHz with spot frequencies to 6 GHz. See the product family standards learning page for guidance on frequency ranges by product type.

Complete Immunity Test Suite — Related Tests

Get Started Today

Need radiated immunity testing? Contact Compatible Electronics for a quote.

Ready to

get started?