Compatible Electronics

EN 55103 EMC Testing for Professional Audio, Video & Entertainment Lighting Equipment

EN 55103 Professional AV Equipment EMC Testing

Compatible Electronics provides comprehensive EN 55103 EMC testing for professional audio, video, audio-visual, and entertainment lighting control equipment. NVLAP accredited for EN 55103-1 (emissions) and EN 55103-2 (immunity) at the Newbury Park location — covering broadcast, stage, studio, and live event professional AV products.

NVLAP AccreditedILAC MRA RecognizedEmissions + ImmunityNewbury Park

What is EN 55103?

EN 55103 is a two-part European product family standard for professional audio, video, audio-visual, and entertainment lighting control equipment. Part 1 (EN 55103-1) covers emissions; Part 2 (EN 55103-2) covers immunity. Unlike consumer multimedia standards (EN 55032 / EN 55035), EN 55103 addresses the unique electromagnetic environments of professional installations — broadcast studios, live event venues, post-production facilities, and entertainment lighting systems.

EN 55103 is harmonized under the EMC Directive 2014/30/EU for professional AV equipment. Both parts are required for a complete CE marking Declaration of Conformity.

Accredited Standards & Environments

Emissions

EN 55103-1 (2009)

  • Accredited at Newbury Park
  • Radiated and conducted emissions
  • Limits based on electromagnetic environment (E1–E5)
  • Disturbance power for applicable equipment types
Immunity

EN 55103-2 (2009)

  • Accredited at Newbury Park
  • Full IEC 61000-4 series immunity test suite
  • Audio quality, video integrity, and lighting control performance criteria
  • Required alongside EN 55103-1 for complete CE marking

Electromagnetic Environments (E1–E5)

E1

Residential

  • Single family dwellings and apartments
  • Strictest emissions limits
E2

Commercial & Light Industrial

  • Offices, shops, hotels, light industry
  • Most common for professional AV installs
E3

Urban Outdoors

  • Open-air concerts and outdoor events
  • Higher immunity levels required
E4

Controlled EMC Environment

  • Broadcast studios, post-production, shielded music studios
  • Relaxed limits reflecting controlled environment

Products Covered

Audio Equipment

Professional Audio

  • Professional mixing consoles (live and studio)
  • Power amplifiers and active loudspeakers
  • Digital audio workstation interfaces and converters
  • Intercom and communication systems
  • Signal processors, equalizers, dynamics processors
  • DMX controllers and interfaces
Video & Lighting

Video & Entertainment Lighting

  • Broadcast cameras and studio cameras
  • Professional video switchers and routers
  • Video production monitors and multiviewers
  • Entertainment lighting controllers (moving lights, LED)
  • Stage lighting dimmers and power distribution
  • Post-production and editing equipment

Performance Criteria for Professional AV

Audio

Audio Quality Maintenance

  • THD, noise floor, and frequency response within spec during immunity tests
  • Criterion A — any degradation unacceptable in live event context
Video

Video Signal Integrity

  • No visible artifacts, sync loss, or frame drops during immunity tests
  • Video quality assessment throughout IEC 61000-4 suite
Lighting

Lighting Control Accuracy

  • DMX signal integrity and fixture response maintained during tests
  • No unintended dimming or colour changes due to disturbances

Real-World Testing Examples

Digital Audio Mixing Console — EN 55103-1 + EN 55103-2 CE Marking

A professional audio manufacturer needed CE marking for a 32-channel digital mixing console for live events and installed sound (E2 and E3 environments). Compatible Electronics performed EN 55103-1 (2009) emissions at Newbury Park — conducted emissions on the AC mains and radiated emissions with all channels active passing representative audio. EN 55103-2 (2009) immunity testing measured audio output level deviation during each test as the Criterion A performance metric. EFT/Burst and conducted RF immunity on balanced XLR ports were the most demanding tests due to long cable runs typical of live event installations. The complete EN 55103-1 + EN 55103-2 CE marking package was delivered from Newbury Park.

Entertainment Lighting Controller — EN 55103-1 + EN 55103-2 + FCC Part 15

A stage lighting equipment manufacturer needed CE marking and FCC compliance for a DMX/RDM lighting controller for entertainment venues (E2 environment). Compatible Electronics performed EN 55103-1 (2009) conducted and radiated emissions and EN 55103-2 (2009) immunity — verifying DMX output signals remained stable during EFT/Burst injection on both AC mains and DMX output ports. FCC Part 15 Subpart B emissions were measured simultaneously via ANSI C63.4. CE marking and FCC compliance were delivered from one session at Newbury Park.

Broadcast Studio Camera — EN 55103-1 Emissions for E4 Broadcast Environment

A broadcast equipment manufacturer needed CE marking for a 4K studio camera for E4 (controlled broadcast studio) deployment with fiber CCU and SDI output. Compatible Electronics performed EN 55103-1 (2009) at Newbury Park at E4 environment limits — with the camera outputting 4K/50p video. The E4 limits reflect the controlled nature of broadcast studios with dedicated power and shielding, providing appropriate limits for professional broadcast facility deployment. Conducted and radiated emissions confirmed compliance, supporting the CE marking Declaration of Conformity for EU broadcast market distribution.

Why Choose Compatible Electronics?

EN 55103-1 & EN 55103-2 Both Accredited

Emissions and immunity at Newbury Park — complete CE marking package.

Professional AV Performance Expertise

Audio quality, video integrity, and lighting control Criterion A assessment.

E1–E5 Environment Testing

All five electromagnetic environment classifications supported.

Combined CE + FCC Testing

EN 55103 + ANSI C63.4 from one session.

ILAC MRA Recognized Reports

Accepted by EU market surveillance for CE marking.

NVLAP Lab Code 200527-0

ISO/IEC 17025:2017 — Newbury Park.

Ready for EN 55103 Professional AV EMC Testing?

Contact us for professional audio, video, and entertainment lighting EMC testing.

Brea: 714‑579‑0500 · Newbury Park: 805‑480‑4044

Ready to